Products >> Industrial RO Membrane >> Seawater RO Membrane
General Information
TaFlux SW series reverse osmosis membrane element offers sustainable consistency, high rejection rate, low energy performance and lower lifecycle cost.
Features & Advantages
- Stable salt rejection rate at high feed TDS
 - Higher permeate flow rate at lower operating fluxes
 - Lower operating cost through reduced energy consumption
 - Economical equivalent element for direct replacement
 
Applications
- Seawater desalination
 - Minimal or zero liquid discharge
 - Landfill leachate sewage treatment
 - High-salinity wastewater concentration
 - Other applications with feed TDS above 10,000 ppm
 
Specifications
- Configuration: Spiral wound element
 - Membrane Polymer: Polyamide thin-film composite
 
Performance
| 
             Element Model  | 
            
             Membrane Active Area ft2 (m2)  | 
            
             Feed Spacer mil (mm)  | 
            
             Permeate Flow Rate* GPD (m3/d)  | 
            
             Stabilized Salt Rejection**  | 
            
             Minimum Salt Rejection  | 
            
             Boron Rejection  | 
        
| 
             TFSW-4040HR  | 
            
             85 (7.9)  | 
            
             28 (0.712)  | 
            
             1,500 (5.7)  | 
            
             99.75%  | 
            
             99.55%  | 
            
             92%  | 
        
| 
             TFSW-4040MR  | 
            
             1,800 (6.8)  | 
            
             99.7%  | 
            
             99.5%  | 
            
             92%  | 
        ||
| 
             TFSW-8040HR  | 
            
             400 (37.2)  | 
            
             6,500 (24.6)  | 
            
             99.8%  | 
            
             99.6%  | 
            
             92%  | 
        |
| 
             TFSW-8040  | 
            
             400 (37.2)  | 
            
             7,500 (28.3)  | 
            
             99.8%  | 
            
             99.65%  | 
            
             91%  | 
        |
| 
             TFSW-8040-440  | 
            
             440 (41)  | 
            
             9,000 (34.1)  | 
            
             99.8%  | 
            
             99.6%  | 
            
             92%  | 
        |
| 
             TFSW-8040-440HF  | 
            
             440 (41)  | 
            
             9,900 (37.5)  | 
            
             99.8%  | 
            
             99.6%  | 
            
             90%  | 
        |
| 
             TFSW-8040-34  | 
            
             400 (37.2)  | 
            
             34 (0.864)  | 
            
             7,500 (28.3)  | 
            
             99.8%  | 
            
             99.65%  | 
            
             91%  | 
        
Element Dimensions


| 
             Size  | 
            
             Length L inch (mm)  | 
            
             Diameter D inch (mm)  | 
            
             Permeate tube inner diameter d inch (mm)  | 
            
             Permeate tube Extension L1 inch (mm)  | 
        
| 
             4040  | 
            
             40 (1,016)  | 
            
             3.9 (99)  | 
            
             0.75 (19)  | 
            
             1.04 (26.5)  | 
        
| 
             8040*  | 
            
             40 (1,016)  | 
            
             7.9 (201)  | 
            
             1.125 (28.6)  | 
            
             /  | 
        
All 8040 elements fit nominal 8.0 inch (203.2 mm) I.D. pressure vessels.
Operating and Cleaning Limits
| 
             Maximum Operating Pressure  | 
            
             1,200 psi (83 bar)  | 
        
| 
             Maximum Operating Temperature  | 
            
             45°C (113°F)  | 
        
| 
             Maximum Chlorine Concentration  | 
            
             0.1 ppm  | 
        
| 
             pH Range, Continuous  | 
            
             2-11  | 
        
| 
             pH Range, Cleaning  | 
            
             1-13  | 
        
| 
             Maximum Feed SDI (15 mins)  | 
            
             5  | 
        
| 
             Maximum Element Pressure Drop  | 
            
             15 psi (1 bar)  | 
        
| 
             Maximum Feed Flow  | 
            
             3.6 m3/h (4040), 17 m3/h (8040)  | 
        
| 
             Minimum Ratio of Concentrate to Permeate Flow for Each Element  | 
            
             5:1  | 
        